TDS1402X GALAXY Interface:
*************************
- Extended to GALAXY-500 (all 4 busses in stead of first two)
- Galaxy zone numbers that CAN'T be captured:
  bus 2, address 15 = 2151 to 2158 (in software 249 to 256)
  bus 4, address 15 = 4151 to 4158 (in software 505 to 512)
- Some enhancements:
  Baud rate 19200 (GALAXY RS232 DIPSWITCH changed!! 7 ON, 8 OFF)
- Software release TDS1402x = version 3.00

***This changes makes PROSOFT 2.66/0 (Eprom Central units 2.66/0)

MORE FUNCTIONS:
**************
more Process, Local moods, IfThenElse, Conditions, Flags, ...
remark: On PROJECT you need all RAM IC's!!!

***This changes makes PROSOFT 2.66/1 (Eprom Central units 2.66/1)

FEEDBACK MOTOR INTERFACES:
************************
When the motor stops after his timeout the feedback-led will not go out.
(workaround: when the first motor is the first motor function in the list this problem will not occur)

***This changes makes PROSOFT 2.66/2 (Eprom Central units 2.66/2)

PROSOFT SCREENS:
***************
In the conditions screen room and icon was not displayed on the checked outputs
In the list of sensor functions was not always UP,DOWN & SWITCH visible
New Language=Hungarian


Process functions & Conditions:
*****************************
You can now also check on Audio, Temperature, Regime, Process, ...

SERVUS SETTINGS:
***************
Possibility to change the place of rooms and items in the list
(some bugs are eliminated)
More functionally for video-door phones .....

PROSOFT UPLOAD:
**************
Bij een upload werden de timed local moods niet opgehaald